Quick Check. PC600 Bar Code Symbol Verifier
Features
. Easy Microsoft®. Windows® 98, Windows ®XP, Windows® 2000, or Windows®NT. Set-Up and Operation
. Test all Major Symbologies Against ISO/IEC or Traditional Parameters
. Interchangeable Optical Input Devices
. Test UCC/EAN-128
. Save Files as Data Files and/or ASCII Text Files
Specification
|
Mechanical |
|
Confi guration:
|
Interface/Input Box, power supply, and choice of mouse scanner, available in aperture sizes of 03, 05, 06, 10,
20 mils, or pen wand in 05, 06, and 10 mils. (Choose visible or infrared for either input device.)
Plugs into PC serial port |
|
Optical Input Connector:
|
9-pin plastic squeeze-to-release male Allows input from any existing or potential future Honeywell interchangeable scanner (excluding laser) |
|
I/O Connector:
|
6-pin modular
Allows for I/O communications with computer |
|
Power Connector:
|
Power jack for powering input device and interface electronics
Uses existing Honeywell QCAC charger |
|
Environmental |
|
|
Operating Temperature: |
32 to 122° F (0 to 50° C) |
|
Storage Temperature: |
14 to 158° F (-20 to 70°C) |
|
Relative Humidity: |
5% to 95% Non-condensing |
|
ESD Sensitivity: |
Withstands 20 attempts to discharge 15Kv to the unit |
|
Sealability: |
Meets NEMA 1 |
|
Shock: |
3 feet (91 cm) to concrete |
|
Safety/Regulatory: |
FCC Class A, CE |
|
Symbologies Verifi ed:
|
Code 39 (1 to 49 characters); Interleaved 2 of 5 (2 to 78 characters); EAN/UPC (-A, -E, -8 and -13) includes magnifi
cation settings in a maximum of 16 steps consisting of: 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 140, 150, 160,
180 and 200%; Coda-bar (1 to 61 characters); Code 128 (1 to 70 characters); Telepen |
|
Applications: |
UCC/EAN-128 |
|
Software |
|
|
Verifi cation Modes:
|
. RL, RD, print contrast signal
. ISO/IEC refl ectance parameters
. Bar/Space dimensional measurement
. Average bar growth/shrinkage
. ISO/IEC decodability
. ISO/IEC 10-scan grade averaging
. Wide-To-Narrow ratio measurements
. Scan profiles on CRT and printer output
. Fixed message length testing
.“X” dimension calculation
. Scan speed variation indication
. Variable or ISO/IEC symbol grade averaging
. Storage of scan results and scan profi les
. Ability to add notations to scan file for later retrieval |
|
Programming Procedures: Report generator allows choice of print format. Click directly on a parameter to configure its setting |
|
Verifi cation Methods: Parameters determined by the ISO/IEC print quality standard or traditional pass/fail criteria |
|
Result Indications:
|
Visual, using an efficient graphical display
Audible, using the PC speaker |
|
Display Organization:
|
. Symbol Grade with Running Average
. Scan Grade
. Symbology and Symbol Data
. Reflectance measurements, including RL, RD, Print Contrast, Rmin/Rmax, Minimum Edge, Contrast, Modulation, and Defects
. Format parameters, including Check Digit and Message Length
. Dimensional results, including Decodability, Intercharacter gap, Wide-To-Narrow Ratio, and Average Bar Error
. Additional results and errors are available in a scrolling list | |